Photon Doppler velocimetry (PDV) is a one-dimensional Fourier transform analysis of a heterodyne laser interferometry, used in the shock physics community to measure velocities in dynamic experiments with high temporal precision. PDV was developed at Lawrence Livermore National Laboratory by Oliver Strand.[1] In recent years PDV has achieved popularity in the shock physics community as an adjunct or replacement for velocity interferometer system for any reflector (VISAR), another time-resolved velocity interferometry system. Modern data acquisition technology and off-the-shelf optical telecommunications devices now enable the assembly of PDV systems within reasonable budgets.

Theory

The fundamental mechanism of PDV is the interference pattern created by two electromagnetic waves with a small difference in frequency. Since most PDV systems are constructed with available telecommunications equipment, a standard laser source for a PDV system is centered at 1550 nm (or 193.4 THz). If this source is then reflected off of a moving surface with some velocity (), the reflected light will be shifted in frequency () according to the relativistic Doppler shift equation.

If the shifted return light is then interfered with the original source, the resulting wave will have a beat frequency in the range of a few GHz. This beat frequency is slow enough that it can be monitored with a simple photo-detector and high speed oscilloscope. By recording the beat frequency over time, a complete velocity history of the surface is obtained.

Beat frequency obtained from the interference of a 193.4 THz EM wave with a 193.40032 THz EM wave. The shifted frequency corresponds to a surface moving toward the observer at a velocity of 500 m/s.

Data analysis

In theory, the analysis of a PDV data signal is quite simple, where the apparent velocity of the moving surface () is simply a function of the source wavelength () and the signal frequency ():

In practice, however, determining the instantaneous frequency () of the signal by inspection can be inaccurate and inefficient. Consequently, Fourier transform analysis is used to extract the most probable frequency components, which can then be used to calculate the velocity history.

By taking sequential FFTs over a time window which moves across the data signal, a 2D spectrogram can be created which indicates the frequency components most dominant in the data. The velocity history can then be extracted from the spectrogram.

Advantages

PDV can measure a wide range of velocities (limited primarily by the time resolution of the signal recording equipment), and is relatively easy to set up and use.

Limitations

Depending on the quality of the data signal and parameters of the FFT, the inherent error in PDV measurements can be high. However, there are ways to mitigate these problems and obtain velocity histories with very high accuracy.[2]

Conferences

The 2009 PDV users conference was held at the University of Texas at Austin, Institute for Advanced Technology.[3] The 2010 PDV users conference was held at the Ohio State University.[4]

See also

References

  1. Strand, O. T.; Goosman, D. R.; Martinez, C.; Whitworth, T. L.; Kuhlow, W. W. (2006). "Compact system for high-speed velocimetry using heterodyne techniques". Review of Scientific Instruments. 77 (8): 083108–083108–8. Bibcode:2006RScI...77h3108S. doi:10.1063/1.2336749.
  2. Dolan, D. H. (2010). "Accuracy and precision in photonic Doppler velocimetry". Review of Scientific Instruments. 81 (5): 053905–053905–7. Bibcode:2010RScI...81e3905D. doi:10.1063/1.3429257. PMID 20515153.
  3. "Photonic Doppler Velocimetry (PDV) Users Workshop<". hdl:1811/52627.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.