Introduction

If the white LED won't light up it may be an issue with the motor. You will need to take the Gravity Light apart and replace the motor.

  1. kbSEYgCjc6yTDfaw
    kbSEYgCjc6yTDfaw
    lnHEJoYi6CICoJXT
    • Flip the GravityLight on its back and place it on a sturdy surface.

    • Unscrew the three 2cm Phillips #00 screws on the back of the GravityLight’s body.

  2. cRbvBmMQ4fVLRaug
    • Some of the internal pieces may loosen or fall out during disassembly.

    • Firmly grasp both parts of the GravityLight body and pull them apart.

  3. oRDRPJKNEVcQdGTJ
    • Take the thicker of the two parts, the back piece, and place it face down on a sturdy surface.

  4. EdoVCPKTdQPawwr6
    • Place the back panel, the larger of the two pieces, on a sturdy surface with its back down.

    • Unscrew the two 2cm Phillips 00 screws on the inside of the back panel.

  5. ggfhUmsh2JV62SDH
    • Watch out for the wires! Keep them attached for this entire guide, or the GravityLight will not work!

    • Gently lift off the LED housing (the white disk).

    • Set the LED housing on the table next to the body of the device.

  6. cIIHNYXYZB5vfbpV
    • Lift off the white piece with four arms.

    • Lift off the black-rimmed gear.

    • Set both pieces aside in a safe place.

  7. WkHrtnobMCGDmVxD
    • Remove the two 2cm Phillips 00 screws from the motor housing.

    • The spring pushing the motor housing may pop out once the motor has been removed.

  8. jp3yJDUOl3MsEACP
    jp3yJDUOl3MsEACP
    C5GBAuJ4UcWml2Pl
    6QDBQTEv3BZ2gJiK
    • Some of the internal pieces may loosen or fall out during disassembly.

    • Firmly grasp both parts of the back panel and pull them apart.

  9. 1SXTkaKxGPENSBBU
    1SXTkaKxGPENSBBU
    JNDobD2C6OI6njZG
    Blsd2aFeRAAOARWd
    • Place the middle section flat with the side that holds the gear system down and locate the back of the motor.

    • Clip the wires close to the soldered joints.

    • Lift the motor out of the middle section. Using the flush wire cutters, clip the red and the blue wires located on the motor's back.

  10. eGcEGvuNSfwEqwNw
Conclusion

To reassemble your device, follow these instructions in reverse order.

Anthony Jungquist

Member since: 26/09/14

125 Reputation

0 comments