The electrical insulation system for wires used in generators, electric motors, transformers, and other wire-wound electrical components is divided into different classes by temperature and temperature rise. The electrical insulation system is sometimes referred to as insulation class or thermal classification. The different classes are defined by NEMA,[1] Underwriters Laboratories (UL),[2] and IEC standards.

For complete electrically operated appliances, the "insulation system" is the overall design of electrical insulation of the energized components to ensure correct function of the device and protection of the user from electric shock.

Temperature classes

IEC 60085
Thermal class[3]
Old IEC 60085
Thermal class[3]
NEMA Class[4] NEMA/UL
Letter class
Maximum hot spot
temperature allowed
Relative thermal
endurance index (°C)[3]
Typical materials
90Y90 °C>90 - 105Unimpregnated paper, silk, cotton, vulcanized natural rubber, thermoplastics that soften above 90 °C[5]
105A105A105 °C>105 - 120Organic materials such as cotton, silk, paper, some synthetic fibers[6]
120E120 °C>120 - 130Polyurethane, epoxy resins, polyethylene terephthalate, and other materials that have shown usable lifetime at this temperature
130B130B130 °C>130 - 155Inorganic materials such as mica, glass fibers, asbestos, with high-temperature binders, or others with usable lifetime at this temperature
155F155F155 °C>155 - 180Class 130 materials with binders stable at the higher temperature, or other materials with usable lifetime at this temperature
180H180H180 °C>180 - 200Silicone elastomers, and Class 130 inorganic materials with high-temperature binders, or other materials with usable lifetime at this temperature
200N200 °C>200 - 220As for Class B, and including teflon
220220R220 °C>220 - 250As for IEC class 200
S240 °CPolyimide enamel or Polyimide films
250250 °C>250As for IEC class 200. Further IEC classes designated numerically at 25 °C increments.

The maximum hot-spot operating temperature is reached by adding the rated ambient temperature of the machine (often 40 °C), a temperature rise, and a 10 °C hot-spot allowance. Electrical machines are usually designed with an average temperature below the rated hot-spot temperature to allow for acceptable life. Insulation does not suddenly fail if the hot-spot temperature is reached, but useful operating life declines rapidly; a rule of thumb is a halving of life for every 10 °C temperature increase.

Older editions of standards listed materials to be used for the various temperature classes. Modern editions of standards are proscriptive, only indicating that the insulation system must provide acceptable life at the specified temperature rise.

In large machines, different systems may be used according to the predicted temperature rise of the machine; for example, in large hydroelectric generators, stator windings may be Class B but the more difficult to cool rotor winding may be Class F.

Categories of insulation

In IEC standards, the insulation system is a classification based on the level of electrical shock protection given to a user. Functional insulation is that required to prevent short circuits within the equipment. Basic insulation is any material added to protect a user from accidental contact with energized parts. Supplemental insulation is rated to withstand 1500 volts AC. Double insulation is a design concept where failure of one insulation system will not expose the user to a shock hazard due to the presence of a second independent layer of insulation. Reinforced insulation is a supplemental insulation system that is strong enough to effectively perform as if a double insulation system was present. Selection of the insulation system is coordinated with the choice of appliance class.[7]

See also

References

  1. "NEMA Insulation Classes". www.engineeringtoolbox.com.
  2. E. Alfredo Campo (ed.), Selection of polymeric materials: how to select design properties from different standards William Andrew, 2007 ISBN 0-8155-1551-0 page 170
  3. 1 2 3 International Electrotechnical Commission Standard 60085 Electrical Insulation- Thermal Evaluation and Designation, 3rd edition, 2004 ,page 11 table 1
  4. NEMA standard MG-1 Motors and Generators
  5. M. A. Laughton, D. F. Warne (ed), Electrical engineer's reference book, 16th edition Newnes, 2003 ISBN 0-7506-4637-3, page 7-3
  6. Donald G. Fink and Wayne H. Beaty (ed), Standard Handbook for Electrical Engineers, Eleventh Edition, Mc Graw Hill, 1978, ISBN 0-07-020974-X, page 7-12
  7. "Understanding IEC Appliance Insulation Classes: I, II and III". Fidus Power. 6 July 2018. Archived from the original on 17 February 2020. Retrieved 16 October 2018.

Further reading

  • Greg Stone (ed.), Electrical insulation for rotating machines: design, evaluation, aging, testing, and repair, Wiley-IEEE, 2004 ISBN 0-471-44506-1
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.