Introduction

This replacement is necessary if the gasket needs replacement.

  1. wfAQNPwnMAkdd6Tk
    wfAQNPwnMAkdd6Tk
    elXTBsEX6mCRT6XM
    • Remove the four screws from the grip with the 5/64" allen wrench. There are two on each side.

  2. OuUPHAOa3E56xx5P
    OuUPHAOa3E56xx5P
    j2SXkRyZbTPtxHuI
    • Pull the grip away from the frame.

  3. Xuye1CPpwkc6TtfM
    Xuye1CPpwkc6TtfM
    pnw2YNIHNGfGbVRV
    • Pull the grip through the opening.

    • The grip is connected in the middle and is one piece.

  4. wOUIYhXEXwfBMaiO
    wOUIYhXEXwfBMaiO
    ElQmEPGrMisqZmF2
    iAWoyGRGwIhHBdIg
    • Remove the macroline from the fitting by pulling the metal ring around the end of the fitting away while pulling out the macroline.

    • It helps to rotate the collar to create room to pull out macroline.

  5. XiQiAFJNSkXLfyBv
    XiQiAFJNSkXLfyBv
    xSXKp4VYJwFWOgt2
    JCHylZlgIoAijQ5M
    • While pulling in the metal ring on the fitting, pull the macroline out.

  6. X2iDiqZVdt4hOXmj
    X2iDiqZVdt4hOXmj
    1htALKtqJLxYKCEM
    XtylUxTflTAYFCLt
    • Use 1/8" allen wrench to remove screw behind regulator.

  7. BbTaAkIfxxASRvkB
    BbTaAkIfxxASRvkB
    tpbPYA1jkwkJZTFn
    xbXmsp41afk6tfWs
    • Use 1/8" allen wrench to loosen the screw inside the grip on the right side.

    • The screw only needs to be turned a couple of times.

    • Slide the upper frame forward on the rails and remove the screw from the slot to separate the two halves of the body.

    • BE CAREFUL: Do not pull the two frames apart too much or too quickly. This may cause the wires to be damaged.

  8. 4dkJvQNd5bKWLQdZ
    4dkJvQNd5bKWLQdZ
    g2Zba5WJuDOuEgsQ
    LBYveC3YjVtxKV6q
    • Using the Phillips #0 screwdriver, remove the 2 screws in the solenoid.

    • Remove the solenoid.

  9. k4xCahFidvHdwLDB
    • Pry the board connection with the 2 black wires from the terminal.

    • BE CAREFUL: Do not pull hard by the wires or you may dislodge them from the connection instead of removing the connection from the board.

    • Pull out the wires through the opening in the top of the grip and replace the solenoid.

  10. 6NlL6OawgFiSmybI
    6NlL6OawgFiSmybI
    xCRFNd3Ofm4MIclC
    QyoWfUYFYR3YmoXY
    • Locate the solenoid gasket manifold, underneath the top half of the body.

  11. kja2w2cqnl65vCrc
    kja2w2cqnl65vCrc
    mEAThnLqPQBiC3Br
    KBWeubaiuOVexMmK
    • Remove the solenoid gasket manifold by applying pressure with one finger to the part closest to the end of the barrel.

Conclusion

To reassemble your device, follow these instructions in reverse order.

Rett Triplett

Member since: 18/10/13

801 Reputation

0 comments