Introduction
In order to remove the manifold assembly, you will need to nearly dismantle the compressor completely. Do not be alarmed, there are just a few key components involved in this to gain access to the manifold assembly. This fact should not hinder you from completing the repair. The guide is straight forward
Tools
-
-
Gently pull the wire attached from the pressure switch to the on/off switch.
-
It should come off the pressure switch with ease.
-
-
-
Unscrew the six 1.75cm screws holding the Pump/Motor Assembly Shroud in place using a phillips #2 screwdriver.
-
Remove the 1cm screw fastening the wires to the pump/motor assembly shroud using a phillips #2 screwdriver.
-
-
-
Gently remove the pump/motor assembly from the shroud.
-
Remove the wire attached from the motor to the pressure switch by gently pulling it free from the pressure switch terminal.
-
Set the pump/motor assembly on your work place next to the compressor.
-
-
-
Remove the manifold assembly by gripping the manifold stem with a smart wrench and twisting in a counter-clockwise direction.
-
-
-
Remove both the Pressure Gauges and the Safety Valve with a Smart Wrench by turning them in a counter-clockwise direction.
-
To reassemble your device, follow these instructions in reverse order.