Introduction
This motor replacement guide should teach you how to dismantle and replace a faulty Motor assembly with little electrical experience required . It would take approximately 30 to 45 minutes to go through these steps. Make sure that you are located in a clean environment with plenty of room to work in as well a descent lighting area.
Tools
Parts
-
-
Using the Philips screwdriver, unscrew the two housing cover screws indicated.
-
using the Philips screwdriver, unscrew the two mounting screws indicated, holding down the Coil Assembly.
-
Using the Philips screwdriver, remove the switch installment screw indicated.
-
-
-
Lift the switch assembly up to loosen the actuating arm.
-
Pull switch button away from actuating arm. Then unclip the actuating arm from the switch assembly.
-
Locate the switch insulation underneath the switch assembly.
-
-
-
Remove stud screw holding down the armature link (the piece on top the wires leading to the Coil Assembly).
-
Locate the Coil Assembly and the power wires leading to the Attached Power cord.
-
-
-
Using the wire stripper, strip the ends of each wire approximately 1-2 cm to reveal enough wire to twist back together with new motor's wires.
-
Next, using the wire cutter, cut the {Positive & Negative} wires that are heading from the Coil Assembly to the Attached power cord. Cut approximately half way between the two ends of both wires.
-
After you cut the old Coil Assembly's wires, remove it completely, and replace it with new one.
-
-
-
Twist the red wire that is coming from the Coil Assembly with the white one, and the black wire with the black one.
-
After you have twisted the wires together, use electrical tape to wrap the stripped wires. Leave some tape over the ends of the wires, and below the cutoff of the rubber around the wire as shown in the photo. Wrap the tape around the wires as tight as possible.
-
To reassemble your device, follow these instructions in reverse order.